Tap Drill Chart: UNC, UNF and Metric
A tap drill is the hole you drill before you tap. Too small and you break the tap. Too large and the threads are shallow and strip. The sizes below target 75 percent thread engagement, which is the standard starting point for steel and most structural work, and which retains roughly 90 percent of the strength of a full thread at a fraction of the tapping load.
UNC coarse thread tap drills
| Thread | Major dia (in) | TPI | Tap drill | Decimal (in) |
|---|---|---|---|---|
| #1-64 | 0.073 | 64 | #53 | 0.0595 |
| #2-56 | 0.086 | 56 | #50 | 0.0700 |
| #3-48 | 0.099 | 48 | #47 | 0.0785 |
| #4-40 | 0.112 | 40 | #43 | 0.0890 |
| #5-40 | 0.125 | 40 | #38 | 0.1015 |
| #6-32 | 0.138 | 32 | #36 | 0.1065 |
| #8-32 | 0.164 | 32 | #29 | 0.1360 |
| #10-24 | 0.190 | 24 | #25 | 0.1495 |
| #12-24 | 0.216 | 24 | #16 | 0.1770 |
| 1/4-20 | 0.250 | 20 | #7 | 0.2010 |
| 5/16-18 | 0.3125 | 18 | F | 0.2570 |
| 3/8-16 | 0.375 | 16 | 5/16 | 0.3125 |
| 7/16-14 | 0.4375 | 14 | U | 0.3680 |
| 1/2-13 | 0.500 | 13 | 27/64 | 0.4219 |
| 9/16-12 | 0.5625 | 12 | 31/64 | 0.4844 |
| 5/8-11 | 0.625 | 11 | 17/32 | 0.5312 |
| 3/4-10 | 0.750 | 10 | 21/32 | 0.6562 |
| 7/8-9 | 0.875 | 9 | 49/64 | 0.7656 |
| 1-8 | 1.000 | 8 | 7/8 | 0.8750 |
UNF fine thread tap drills
| Thread | Major dia (in) | TPI | Tap drill | Decimal (in) |
|---|---|---|---|---|
| #0-80 | 0.060 | 80 | 3/64 | 0.0469 |
| #2-64 | 0.086 | 64 | #49 | 0.0730 |
| #4-48 | 0.112 | 48 | #42 | 0.0935 |
| #6-40 | 0.138 | 40 | #33 | 0.1130 |
| #8-36 | 0.164 | 36 | #29 | 0.1360 |
| #10-32 | 0.190 | 32 | #21 | 0.1590 |
| 1/4-28 | 0.250 | 28 | #3 | 0.2130 |
| 5/16-24 | 0.3125 | 24 | I | 0.2720 |
| 3/8-24 | 0.375 | 24 | Q | 0.3320 |
| 7/16-20 | 0.4375 | 20 | 25/64 | 0.3906 |
| 1/2-20 | 0.500 | 20 | 29/64 | 0.4531 |
| 9/16-18 | 0.5625 | 18 | 33/64 | 0.5156 |
| 5/8-18 | 0.625 | 18 | 37/64 | 0.5781 |
| 3/4-16 | 0.750 | 16 | 11/16 | 0.6875 |
| 7/8-14 | 0.875 | 14 | 13/16 | 0.8125 |
| 1-12 | 1.000 | 12 | 59/64 | 0.9219 |
Metric coarse tap drills
Metric coarse is the easy one: subtract the pitch from the major diameter and you have the drill.
| Thread | Pitch (mm) | Tap drill (mm) |
|---|---|---|
| M3 | 0.50 | 2.50 |
| M4 | 0.70 | 3.30 |
| M5 | 0.80 | 4.20 |
| M6 | 1.00 | 5.00 |
| M8 | 1.25 | 6.80 |
| M10 | 1.50 | 8.50 |
| M12 | 1.75 | 10.20 |
| M14 | 2.00 | 12.00 |
| M16 | 2.00 | 14.00 |
| M20 | 2.50 | 17.50 |
| M24 | 3.00 | 21.00 |
| M30 | 3.50 | 26.50 |
| M36 | 4.00 | 32.00 |
Clearance drills
A clearance hole is the through hole the bolt passes without threading. Close fit for located joints, free fit where you need assembly tolerance.
| Bolt size | Close fit | Free fit |
|---|---|---|
| #6 | #27 (0.1440) | #18 (0.1695) |
| #8 | #18 (0.1695) | #9 (0.1960) |
| #10 | #9 (0.1960) | #2 (0.2210) |
| 1/4 | 17/64 (0.2656) | 9/32 (0.2812) |
| 5/16 | 21/64 (0.3281) | 11/32 (0.3438) |
| 3/8 | 25/64 (0.3906) | 13/32 (0.4062) |
| 1/2 | 33/64 (0.5156) | 17/32 (0.5312) |
| 5/8 | 41/64 (0.6406) | 21/32 (0.6562) |
| 3/4 | 49/64 (0.7656) | 25/32 (0.7812) |
The formula
If the size you need is not on the chart, calculate it:
Tap drill (in) = major diameter − (0.974 ÷ TPI) for 75 percent thread
For 1/4-20: 0.250 − (0.974 ÷ 20) = 0.250 − 0.0487 = 0.2013, which rounds to a #7 drill at 0.2010.
For metric coarse at 75 percent, simply: drill = major diameter − pitch. M8 x 1.25 gives 6.75, and the standard 6.8 mm drill is the practical choice.
The general form, for any engagement percentage, is major diameter minus (1.299 × percent ÷ 100 ÷ TPI). Pick the nearest standard drill above the calculated value rather than below it.
Choosing thread percentage
| Engagement | When to use it |
|---|---|
| 50 – 60% | Tough or gummy material, deep holes, hardened stainless, large diameters. Much lower tapping torque and far fewer broken taps. |
| 65 – 70% | A common production compromise, and the usual target for roll-form tapping. |
| 75% | The default on every standard chart. Steel, aluminum, ordinary depths. |
| Above 80% | Rarely worth it. Tapping torque climbs steeply for almost no strength gain. |
Thread strength does not scale with engagement the way people expect. Going from 75 to 100 percent adds a few percent of strength and roughly doubles the torque on the tap. In a hard alloy, that is the difference between a finished part and a broken tap in a nearly finished part.
Common questions
What size drill for a 1/4-20 tap?
A #7 drill, 0.201 inches, for 75 percent thread engagement. In tougher material a #8 or 13/64 gives a lower engagement and a much easier tap.
What is the tap drill for 10-32?
A #21 drill, 0.159 inches, at 75 percent thread.
What drill size for an M8 tap?
6.8 mm for M8 x 1.25 coarse. For metric coarse the rule is simply major diameter minus pitch.
Why is 75 percent thread the standard?
Because it keeps nearly all the strength of a full thread while cutting the tapping torque dramatically. At 75 percent engagement a thread retains roughly 90 percent of full-thread strength, and the tap is far less likely to break.
What happens if the tap drill is too big?
The threads are shallow. The joint will strip at a lower load than the fastener is rated for, and in a critical application that is a failure the inspection may not catch.
Should I use a different drill for aluminum?
Often, yes, but in the other direction from what people assume. Soft materials tap easily, so a higher engagement is affordable. The materials that need a lower engagement and a larger drill are the tough ones: stainless, A286, Inconel and other high-nickel alloys.
Related pages
Thread pitch chart · Bolt and screw size chart · Bolt grade chart · NPT thread chart · Bolt and stud weight calculator
Need threaded parts made?
Eastwood Manufacturing machines threaded fasteners and components to print, including internal threads in stainless, A286, Inconel and other alloys where tapping is the hard part of the job.
Request a quote sales@emfasteners.com
Chart values are standard published tap drill sizes for reference. Verify against your tap manufacturer's recommendation and the controlling drawing before production.